If you have any issues viewing the data, please Be aware of your private generation configuration options and system limitations. For example, a recent 200 kWac project in Rhode Island learned when the interconnection application was submitted that no additional solar power was on either the local circuit or at the substation. Estimated savings based on average retail price of $0.08 per kWh for commercial customers based on 2018 Energy Information Administration data for the state of Illinois. Interconnection is the process of connecting a distributed generation system to the electric grid. pv magazine offers daily updates of the latest photovoltaics news. Notify me of follow-up comments by email. New York City Coverage by the Numbers 750,000+ buildings in the city 5 billion square feet of floor space 3 million housing units 30 percent one- and two-family residences Notify me of follow-up comments by email. The tool functions well, as intended, to provide developers of large DERs early insight into grid locational hosting capacity. In the Commissions July 2020 order, the Commission adopted a long-term goal to use the hosting capacity analysis in the interconnection processs fast track screens. The Commissions July 2020 Order also required the Company to study three additional objectives for hosting capacity analysis: These objectives set the Commissions intentions for hosting capacity analysis to, at the least, augment initial review screens and, at the most, totally automate interconnection studies. Additional information includes total solar already on the circuit, the circuits voltage, whether the circuit is three phase or single phase, and a range of substation bank information. Its also clear that hosting capacity could play an important role in addressing timeliness in processing the interconnection of distributed energy resources. The US PLSS is used to subdivide and describe land. Legal Notice Terms and Conditions Privacy Policy pv magazine 2023, Welcome to pv magazine USA. The US PLSS is used to subdivide and describe land. Additionally, we have provided the peak substation load for the previous year. But by the time the projects interconnection was returned, a 5 MWac solar project had won approval at the substation. Beyond the pending integration into interconnection, California utilities have additional features on their hosting capacity maps that ILSR believes should be implemented in Minnesota. Con Edison does not warrant the accuracy of these informational forecasts. Your completed pre-application and associated fees (in the form of a check or money order, only; do not send cash) should be sent to the following address: ComEdAttn: Interconnection Services Department2Lincoln Center, 9th FloorOakbrook Terrace, IL 60181Email our Interconnection Team. The platform will forecast, plan, interconnect, monitor, control, and effectively manage the integration of local generation resources into our existing electric distribution system. A technical error has occurred. Californias process to incorporate hosting capacity analysis into the interconnection process began in 2014, so we understand that this will take some time. Share to Facebook. You may submit your application for Level 1 Distributed Generation Interconnection or Levels 2, 3 or 4 Distributed Generation online. In the same ruling, Xcel was ordered to create a better process for addressing interconnection complaints (by June 2021). The 3-year, 8,760 network forecast utilizes the General Electric-Multi-Area Reliability Simulation (GE-MARS) program to modify the actual hourly loads from the previous year based on monthly energy distribution from the previous year, forecasted peak demand, and energy send-out. We ask that the Commission require Xcel Energy to provide these violations in the HCA map pop-ups (as requested by the Commission in the July 2020 order), rather than just in the sub-feeder Tabular Results. Xcel petitioned to, as mentioned in the Hosting Capacity Analysis report, allow publicly posting additional information on CSGs in the interconnection queue, including feeder name, currently expected in-service date, and indicative interconnection cost. ILSR supports the publication of this information, as an interest in greater transparency was raised in the October 2, 2020 convening of the Distributed Generation Working Group. Circuit level data is visible when zoomed below the sixteenth-section scale. Don't miss a single report, infographic, or podcast! Since then, multiple states have created legal requirements forcing electric monopolies to share their power grid data with solar developers via what are known as Hosting Capacity Analysis (HCA) maps. As it turned out, the larger-scale ground mount project was moving slowly due to local resistance. Washington, DC and part of Maryland: Potomac Electric Power Company map; Last year, ComEd in Illinois also published a hosting capacity map. Apply Now. 1. The Commission should accept Xcel Energys 2020 Hosting Capacity Analysis Report, but we submit the following concerns about the Report and suggest additional development to advance the common goals of customers and the Commission. LSRV areas will display a status of Eligible on the Hosting Capacity map under LSRV Area Information. For more on LSRV, VDER and the Value stack, visit our Private Generation Tariffs page. Your email address will not be published. Please enable scripts and reload this page. We adjust the load shapes to the individual network peak demand and energy send-out forecasts, including the projected DER impacts, such that the forecast includes the impact of load modifiers. Required fields are marked *. You may not have a full-fledged data center but your facility has a space housing your server or at least some networking equipment. An SDG&E spokesperson provided this comment: SDG&E has continuously innovated, tested and improved the HCA tool by working with key stakeholders, including IREC and CPUC staff, to develop and refine the methodology. GwfaaLLI'U:gp*= G}.a[8. Touch device users, explore by touch or with swipe gestures. This article originally posted atilsr.org. View interconnection queue information for all Distributed Generation or Distributed Storage Resource Projects. Please see Part 466 for specific qualification requirements (screens) for each interconnection level. As a solar developer and individual cheering for a strong power grid, few pieces of data are as useful as site data sorted by grid demand. stream See Xcel Energys hosting capacity map for Minnesota below. ComEd's electric distribution system is dynamic and ComEd will provide periodic updates to the hosting capacity map. Subject to your specific situation, ComEd's response may require further action to be taken and/or further expense to be incurred by you in order to complete the interconnection. Each section is further subdivided into quarter-sections (1/2 mile X 1/2 mile). This data is being provided for informational purposes only and is not intended to be a substitute for the established interconnection application process. View interconnection queue information for all Distributed Generation or Distributed Storage Resource Projects. John Farrell directs the Energy Democracy initiative at the Institute for Local Self-Reliance and he develops tools that allow communities to take charge of their energy future, and pursue the maximum economic benefits of the transition to 100% renewable power. Log in using your email address if you've already registered. It looks like your browser does not have JavaScript enabled. The interactive map displays the highest circuit hosting capacity at the: Township, Section, Quarter-Section, Sixteenth-Section, and circuit level. Whether you're a customer, contractor, or developer, our interactive But the inefficient air conditioning units preventing your servers from overheating may be costing you more in energy costs and maintenance fees every month. Link leads to external site, Share to Mail. It does not appear on display pages. Xcel has stated in the HCA report that the Company is committed to make the interconnection process work better. ILSR asks that the Commission hold them to that with specific, time-bound deadlines. pv magazine USA offers daily updates of the latest photovoltaics news. The hosting capacity analysis is conducted under current configurations. Our interactive portal can help guide decisions regarding the interconnection of resources. Going significantly beyond this amount would likely require a combination of upgrades by ComEds infrastructure, potentially higher interconnection costs and deployment of technologies like energy storage. pv magazine USA offers daily updates of the latest photovoltaics news. DER hosting capacity is a function of resistance on any circuit Fact: DER hosting capacity increases w/nominal voltage . Any other transfer to third parties will not take place unless this is justified on the basis of applicable data protection regulations or if pv magazine is legally obliged to do so. endobj A hosting capacity map displays a high-level estimate of the available hosting capacity for adding DG. You may be trying to access this site from a secured browser on the server. A decade ago, resources for scouting viable locations for new distributed energy resources (DER) simply did not exist. Hosting Capacity is an estimate of the amount of DER that may be accommodated under current configurations at the overall circuit level without significant systemupgradesto address adverse impacts to power quality or reliability. Apply Now. Grid security is a vital issue, but we fear it may serve as an excuse to further delay the interconnection of distributed generation. In summary, there are 5 things we ask of the Commission: Thank you for the opportunity to comment and for taking up this important conversation; we appreciate that there has not been any legislative preemption of this regulatory process. Why is Connecting Clean Energy to the Grid So Hard? This site uses cookies. x\r8}wTw*YNdc!88RV'O]t )$DZIIOF ys=N~=hAs`9Dr3N%_+E6'0QMwx4SJ\ip_NOuzr-2j#b/)eJm ! When autocomplete results are available use up and down arrows to review and enter to select. If you have more to contribute, please comment with a link. ComEd Delivery Customer Class Peak Load Contributions Customer Delivery Classifications Delivery Class Code Network Peak Load Contribution (NSPL) kW Capacity Peak Load Contribution (PLC) kW Capacity Peak Load Contribution (PLC) kW. For example, according to Xcel Energys integrated resource plan filing (Docket 19-368), future development of distributed generation resources will be meager. However, if the Commission does not apply greater pressure for action, hosting capacity may continue to be a largely performative exercise without providing tangible benefits to Minnesota stakeholders and electric customers. Please be mindful of our community standards. The hosting capacity map utilizes the United States Public Land Survey System (US PLSS) to present results. A PG&E spokesperson commented that To date, PG&E has connected more than475,000 solar customers to the electric grid and supports customers with resources before, during and after they go solar.. Further information on data privacy can be found in our Data Protection Policy. You may revoke this consent at any time with effect for the future, in which case your personal data will be deleted immediately. That meant solar developers had zero access to critical power grid connection information, substation status, and other local solar plant connections. Whether youre a customer, contractor, or developer, our interactive maps can help you identify potential sites for private generation. Your completed application and associated fees (in the form of a check or money order, only; do not send cash) should be sent to the following address: ComEd Attn: Interconnection Services Department Two Lincoln Center, 9 th Floor Oakbrook Terrace, IL 60181 Email our Interconnection Service Department 1-630-576-8158 Interconnection Gui delines The ComEd Energy Efficiency Program is funded in compliance with state law. It divides the ComEd service territory into townships (6 miles X 6 miles). "The hosting capacity map will be stale soon after it's published," he said. The highest capacity locations are seen in dark blue. The IREC paper describes how some utilities have worked to ensure accurate inputs to their hosting capacity analysis, and use automated flags to identify anomalous modeling results. Please note that this analysis was conducted under current configurations, without installed DER, and prior to infrastructure upgrades such as; installing a recloser or remote terminal unit at the Point of Common Coupling, replacing a voltage regulating device or controller to allow for reverse flow, substation-related upgrades including 3V0 protection, or other protection-related upgrades. Tel 289-387-1025, 'Electricity out of essentially nothing': Invention creates power from falling snow, New Rules for a Future Puerto Rico Microgrid Landscape, Petrochemical plants will diversify economy, create jobs, China, Cambodia agree to nuclear energy cooperation, Electricity System More Accountable to Nova Scotians, Arc Flash Training - CSA Z462 -2021 - Certified Electrical Safety Instruction, Electrical Grounding For Telecommunications Systems, Grounding and Bonding and The NEC - Section 250, Combined NFPA 70e LV Arc Flash And HV Electrical Safety, Short Circuit Study & Protective Device Coordination, Arc Flash Analysis/Study - IEEE 1584 Update, 30 Hour Electrical Power System Training - Power System Fundamentals (March 10, 2023, Short Circuit Study & Device Coordination (March 16-17, 2023), Arc Flash Analysis (March 23-24, 2023), Electrical Safety Awareness Training For Non Electrical Workers - Live Online Instructor-Led Training, Lightning Protection Systems Training For Utility, Industrial, Commercial & Institutional power systems, Combined CSA Z462 LV & HV Electrical Safety Training, Fire Alarm Training Online - Life Safety Equipment & Systems - Design, Installation, Inspection, Testing, Service & Maintenance, Grounding and Bonding Training And The CE Code. Ultimately, a published set of best practices for validating hosting capacity maps is needed, the paper says, so that stakeholders and regulators know if utilities are performing a comprehensive data validation effort.. . This hosting capacity data is provided for informational purposes only and is nota substitute for the established interconnection application process. Zoom in (+) and zoom out (-) icons are available to the left of the search tool bar. Register with an email address to update your login credentials. 1885 Clements Rd, Unit 218 In at least five more states, regulators are considering requiring utilities to produce such maps, or to improve the maps they are already publishing, Zakai said: Colorado, Illinois, Michigan, Massachusetts and New Hampshire. Circuit configurations can change for various reasons. The watchword is actionable. If the maps arent actionable (b/c theyre not accurate) they re actually worse than useless. We provide localized 8,760 hour forecasts to assist developers in considering the application of DER in our service territory. In general, this section applies to larger generators (e.g., Commercial Wind Farms, Biomass or Solar Projects). Modeling experts could determine what those additional checks should be, the paper says. This data can be accessed by selecting a feeder or network on the mapping display and advancing to the associated data pane. This tool isnt applicable for the vast majority of DER project planning (around 98%) in SDG&Es service territory. Each quarter section is further subdivided into sixteenth-sections (1/4 mile X 1/4 mile). From what you need to develop an individual residential project, to Community Solar, and all the way up to a large industrial project. Maria McCoy is a Researcher with the Energy Democracy Initiative. Solar developers take on module manufacturing risk. To its merits, ILSR offers the following question to Xcel Energys refusal to follow Commission orders: as several members of the Hosting Capacity Analysis and Distribution Grid Data Security Workshop pointed out, both New York and California IOUs disclose feeder lines on their hosting capacity maps. Click on a Township, Section, Quarter-Section, Sixteenth-Section, or circuit to display the maximum hosting capacity value. Synchronous Generation and System Fault Current Limitations. The Electricity Forum (In Canada) From schools, local government buildings and fire and police stations to offices, medical facilities and more, each facility has a room storing networking equipment or at least a small server stack. Link leads to external site, Share to LinkedIn. The Minnesota Public Utilities Commission has required that Xcel Energy, the largest electricity provider in Minnesota, conduct annual hosting capacity analysis reports since 2016. Required fields are marked *. hosting capacity map can help you identify potential sites for the interconnection of Distributed Energy Resources (DER) to ComEd's distribution circuits. To smooth the process of integrating DER, ComEd is developing and implementing technologies, like a hosting capacity map, so stakeholders can make informed decisions about where to install generation, like PV, as well as technologies to accelerate the interconnection process for smaller quantities of generation. The Interconnection Queue Report provides the following minimum information for all Distributed Generation (Excluding Level 1 Applications) or Distributed Storage Resource Projects for which a queue position has been assigned: Each substation and feeder where an interconnection will be made is identified in the reported data by a unique index number assigned for the purpose of reporting interconnection queue information and not by any geographic or operational designation or description. Processing: Hosting Capacity map added on August 11, 2017. The analyses represent the overall feeder level hosting capacity only, and do not account for all factors that could impact interconnection costs (including substation constraints). However, ILSR feels there are three issues worth addressing in this docket: 1) Xcel slows the adoption of cost-effective distributed generation, 2) Xcel has not fulfilled the requirements outlined in the Public Utility Commissions July 2020 Order, and 3) Xcel could do more to advance toward the ultimate goal: delivering its customers more cost-effective clean energy by integrating hosting capacity analysis with the interconnection process. Each township is subdivided into 36 sections (1 mile X 1 mile). o Customer/Utility information sharing portal w/maps showing DER hosting capacity & locations where EV . We also offer comprehensive global coverage of the most important solar markets worldwide. These values are representative of the total amount of DG that is installed on the feeders and networks associated with the area substation. Read our policy. In Georgia, solar groups last year called for state regulators to require Georgia Power to produce such maps. The Company updates the information provided based on data that is current as of a specific point in time and neither that data nor the queue is represented to be, and may not be relied upon to be, current, complete, or accurate as of any future date. Although the values are meant to provide the user with a general idea of availability, space on the . ComEd will provide the pre-application data to the potential application within 20 business days after receipt of the completed pre-application report request form and payment of the $300 fee. Over time, a location may produce different circuit results. Link leads to external site, Share to Twitter. We publish electrical technical handbooks and associated digital magazine advertising supplements. The Hosting Capacity data that is being provided is for information purposes only and is not intended to be a substitute for the established interconnection process. Updates: Last updated in February/March 2017, with exception of Hosting Capacity map & supporting Portal documents. The three utilities, PG&E, SCE and SDG&E, agreed that the questionable load results warrant investigation and refinement of their methodology, the paper says. The hosting capacity map utilizes the United States Public Land Survey System (US PLSS) to present results. The IREC paper is titled Validation is critical to making hosting capacity analysis a clean energy game-changer.. As raised in a July 2020 Order by the Minnesota Public Utilities Commission, an improved hosting capacity analysis could be used to streamline the interconnection process of plugging solar into the electric grid. Given the proper policies and incentives, like robust hosting capacity analyses, distributed solar development can serve as a tool for economic stimulus and increased energy justice nationwide. What this does indicate is that a densely populated community like Oak Park would most likely have to get the majority of its solar and renewable electricity from outside its boundaries to reach the statewide RPS goal of 25%. An expedited review of the interconnection request under Levels 1 - 3 is available provided the proposed DG facility passes the screens outlined in Part 466 and does not require construction of facilities by ComEd to protect reliability and accommodate the interconnection of the DG facility. Utility National Grid operates in Rhode Island and illustrates local line capacities with its HCA map. Each township is subdivided into 36 sections (1 mile X 1 mile). The Company requested that the Commission excuse the complaints from the Quality of Service Plan, a request that the Commission denied. The next step beyond ensuring accuracy and actionability is automating interconnection applications based on specific map grid circuits and line sections, with click and claim capabilities that link these maps with automated interconnection portals. The Department finds that hosting capacity maps can inform the interconnection process and can be a useful tool for interconnecting customers to identify low-cost/no-cost interconnection locations or otherwise inform their investment decisions. You may be trying to access this site from a secured browser on the server. Developer submits the interconnection requestand hopes for the best. Please contact our Customer Care Center if you have questions. The utility will also have to provide downloadable data of line segments with limitations they may have for adding capacity at different connection spots. Electricity Forum publishes Electricity Today T&D Magazine and Intelligent Power Today Industrial Electrical Magazine. Pickering, ON We install Massachusetts residential solar via Whaling City Solar. The Institute for Local Self-Reliance (ILSR) respectfully submits the following comments on Xcel Energys 2020 Hosting Capacity Report. The Commission should, after considering stakeholder input in Docket No. uqJF$ The hosting capacity analysis represents the overall circuit level hosting capacity only, and does not account for all factors that could impact interconnection costs (including substation constraints). An application fee is charged for each interconnection application submitted. The Interconnection Queue Report is intended to provide interconnection information according to the terms and conditions of ComEds Rider IQ Tariff. Granularity increases as users zoom in. Integrating hosting capacity analysis with the interconnection process is not only possible, it is already being done. You can remove a saved URL to remember another. 12 of the July 2020 Order, the Commission directed the Company, to the extent practicable, show the actual locations of distribution system lines instead of broad blocks of color on the HCA map. Parts of the grid that are constrained are marked with red lines (the area around number 1), while parts of the grid with available hosting capacity are marked with green and yellow lines (the area around number 2). 1 0 obj Peak and Minimum Load Duration Curves Xcel . I was involved in various CPUC regulatory proceedings on these maps and made the same kinds of comments frequently. No matter the facility type, you can improve the overall energy efficiency of your IT room and keep your computer equipment running while also saving money. Save my name, email, and website in this browser for the next time I comment. It may also speed up the interconnection process; if developers can split an upgrade charge with other projects in the queue for that same feeder, they may be less likely to withdraw their application in the final stretch. Here are a few upgrades you can implement to help you get started: Airflow management - Reduce energy use up to 20% by preventing cool supply air from mixing with the hot air released from IT equipment. The pre-application report produced by ComEd is non-binding and does not confer any rights; the potential applicant must file an application before it can interconnect with the ComEd system. Also, the map is taken from data as of a point in time and updated as of the date indicated in the pop-up display on the map, and therefore may not reflect current conditions in a given area. Southern California Edisons hosting maps contain a built-in function enabling users to filter sites based on available capacity above a certain threshold. These tools make it so every stakeholder in the process is able to work more efficiently and save the entire system precious time + money.
Kris Jenner House Hidden Hills Address, Glynis Barber And Michael Brandon Wedding, Bang Energy Drinks And Heart Problems, Articles C